Samsung SAMRNS09ABT

Samsung WindFree™ AR09TSFABWKNCV RNS09ABT Single-Zone Split System Indoor Unit, 208 - 230 V, 1 ph -Phase

Manufacturer: Samsung
Part #: SAMRNS09ABT
Customer Part #:
Login for Availability
Login for Price
Amperage Rating      :      1/2.8/5.2 A Cooling, 1/3.4/9.8 A Heating
BTU Rating      :      9000 Btu/hr Cooling,11000 Btu/hr Heating
CFM Rating      :      1589 cfm Condenser, 251 to 392 cfm Cooling, 286 to 427 cfm Heating Evaporator
Connection Type      :      Flared
Drive Type      :      Inverter
EER Rating      :      15.5
Frequency Rating      :      60 Hz
Fuse Rating      :      20 A
HSPF Rating      :      12.5
Model      :      AR09TSFABWKNCV
Mounting Type      :      Wall
Number of Fan Speeds      :      3
Overall Height      :      11-3/4 in
Overall Length      :      8-7/16 in
Overall Width      :      35 in
Phase      :      1 ph
Power Rating      :      40 W Condenser, 27 W Evaporator
SEER Rating      :      24.5
Sound Level      :      22 dBA, 38 dBA
Temperature Rating      :      61 to 90 deg F Cooling, 81 deg F Heating
Voltage Rating      :      208 - 230 V

Samsung WindFree™ Single-Zone Split System Indoor Unit, Model: AR09TSFABWKNCV, 208 - 230 V, 1/2.8/5.2 A Cooling, 1/3.4/9.8 A Heating, 40 W Condenser, 27 W Evaporator, 60 Hz, 1 ph Phase, 3 Fan Speeds, 9000 Btu/hr Cooling,11000 Btu/hr Heating, 1589 cfm Condenser, 251 to 392 cfm Cooling, 286 to 427 cfm Heating Evaporator, 15.5 EER Rating, 24.5 SEER, 12.5 HSPF, Flared Connection, 20 A Fuse Rating, Inverter Drive, 22 dBA, 38 dBA Sound Level, Wall Mounting, 61 to 90 deg F Cooling, 81 deg F Heating, 8-7/16 in Overall Length, 35 in Overall Width, 11-3/4 in Overall Height

  • The Samsung Max Heat system shall provide 100% heating capacity at 5 degF outdoor temperature and high heating capacity at -13 degF outdoor temperature
  • The outdoor unit shall have a base pan heater as standard to ensure optimal defrost cycle water drainage
  • The indoor unit shall feature "Wind-Free™" mode*. In cooling mode, as room temperature nears set temperature, the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit preventing cold air drafts on occupants
  • The indoor unit shall have Wi-Fi capability as standard
  • Outdoor unit shall provide 208/230 V power to indoor unit via 14 AWG X 3 interconnect power cable
  • Catalog https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RNS09ABT_Catalog.pdf
  • Instruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RNS09ABT_Instruction_Installation_Manual.pdf
  • Owners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RNS09ABT_Owners_User_Manual.pdf
  • Service Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_JNH09JDT_Service_Manual.pdf
  • Submittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_RNS09ABT_Submittal.pdf